Original Factory Vicks Servo Drive Taiwan Delta Supply to Latvia
Original Factory Vicks Servo Drive Taiwan Delta Supply to Latvia Detail:
Vicks Servo System Delta Drive
Technical Data
460V | Frame | C | D | E0 | E3 | E2 | |||||||||
Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
General Specifications | Control Method | SVPWM | |||||||||||||
Speed Detector | Resolver | ||||||||||||||
Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Feedback Command | DC 0~10V | ||||||||||||||
General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
Over-current | 300% of rated current | ||||||||||||||
Ground leakage current | Higher than 50% rated current | ||||||||||||||
Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
Over-temperature | Built-in Temperature Sensor | ||||||||||||||
Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
Operation Temperature | -10℃~45℃ | ||||||||||||||
Storage Temperature | -20℃~60℃ | ||||||||||||||
Humidity | 90% RH (non-condensing) | ||||||||||||||
Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
Certifications | CE |
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:
Related Product Guide:
Why every website owner needs Google Analytics
We're convinced that with joint endeavours, the business between us will bring us mutual benefits. We are able to guarantee you products high quality and competitive value for Original Factory Vicks Servo Drive Taiwan Delta Supply to Latvia, The product will supply to all over the world, such as: United Arab Emirates, Jamaica, Haiti, During the short years, we serve our clients honestly as Quality First, Integrity Prime, Delivery Timely, which has earned us an outstanding reputation and an impressive client care portfolio. Looking forward to working with you Now!
By James Brown from Plymouth - 2017.12.31 14:53
It is not easy to find such a professional and responsible provider in today's time. Hope that we can maintain long-term cooperation.
By Austin Helman from South Africa - 2017.09.09 10:18