Good Quality Vicks Servo Drive Taiwan Delta Supply to Hungary
Good Quality Vicks Servo Drive Taiwan Delta Supply to Hungary Detail:
Vicks Servo System Delta Drive
Technical Data
460V | Frame | C | D | E0 | E3 | E2 | |||||||||
Model Number VFD-___VL43_-J | 055A | 075A | 110A | 150B | 185B | 220A | 300B | 370B | 450B | 550A | 750A | ||||
Power (kW) | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | 37 | 45 | 55 | 75 | ||||
Horsepower (HP) | 7.5 | 10 | 15 | 20 | 25 | 30 | 40 | 50 | 60 | 75 | 100 | ||||
Output | Max. Current (A) (continuous 60 seconds ) | 21 | 27 | 36 | 46 | 58 | 62 | 102 | 124 | 155 | 187 | 255 | |||
Max. Current (A) (continuous 20 seconds ) | 25 | 32 | 42 | 54 | 68 | 78 | 120 | 146 | 182 | 220 | 300 | ||||
Input Current (A) | 14 | 18 | 24 | 31 | 39 | 47 | 56 | 67 | 87 | 101 | 122 | ||||
Power | Input Voltage Tolerance | 3-Phase 380~480V, 50/60 Hz | |||||||||||||
Mains Voltage Tolerance | ±10% (342-528V) | ||||||||||||||
Mains Frequency Tolerance | ±5% (47-63Hz) | ||||||||||||||
Weight (kg) | 8 | 10 | 10 | 10 | 10 | 13 | 13 | 28 | 36 | 50 | 50 | ||||
General Specifications | Control Method | SVPWM | |||||||||||||
Speed Detector | Resolver | ||||||||||||||
Speed Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Input Command | DC 0~10V, support 3-point adjustment for analog inputs | ||||||||||||||
Pressure Feedback Command | DC 0~10V | ||||||||||||||
General Input Signal | 5 ch DC24V 8mA | ||||||||||||||
General Output Signal | 2 ch DC24V 50mA, 1 ch Relay output | ||||||||||||||
Analog Output Voltage | 1 ch dc 0~10V | ||||||||||||||
Optional Accessories | Speed Feedback PGA Card | Necessary (EMVJ-PG01R) | |||||||||||||
Brake Resistor | Necessary (refer to appendix A) | ||||||||||||||
Pressure Sensor | Necessray, only pressure sensors with output signal 0~10V can be used ( max. pressure value can be set by Pr. 00~08) | ||||||||||||||
EMI Filter | Optional ( refer to Appendix A) | ||||||||||||||
Protections | Motor Protection | Electronic thremal relay protection | |||||||||||||
Over-current | 300% of rated current | ||||||||||||||
Ground leakage current | Higher than 50% rated current | ||||||||||||||
Voltage Protection | Over-voltage Level: Vdc>400/800V; Low-voltage Level: Vdc<200/400V | ||||||||||||||
Mains Input Over-Voltage | Varistor (MOV) | ||||||||||||||
Over-temperature | Built-in Temperature Sensor | ||||||||||||||
Environment | Protection Level | NEMA 1/IP20 | |||||||||||||
Operation Temperature | -10℃~45℃ | ||||||||||||||
Storage Temperature | -20℃~60℃ | ||||||||||||||
Humidity | 90% RH (non-condensing) | ||||||||||||||
Vibration | 1.0G 20Hz, 20~60Hz 0.6G <20Hz: 1.0G, 20 to 60 Hz: 0.6G | ||||||||||||||
Cooling System | (RUN, STOP) Force cooling (RUN, STOP) | ||||||||||||||
Installation Location | Altitude 1,000m or lower (keep away from corrosive gasses, liquid and dust) | ||||||||||||||
Certifications | CE |
Note: Bulit in brake chopper for models 22kw and below
Product detail pictures:
Related Product Guide:
Why every website owner needs Google Analytics
With sophisticated technologies and facilities, strict top quality handle, reasonable value, exceptional support and close co-operation with clients, we are devoted to furnishing the ideal worth for our clients for Good Quality Vicks Servo Drive Taiwan Delta Supply to Hungary, The product will supply to all over the world, such as: Slovakia, panama, Kyrgyzstan, Ensuring high product quality by choosing the best suppliers, now we have also implemented complete quality control processes throughout our sourcing procedures. Meanwhile, our access to a large range of factories, coupled with our excellent management, also ensures that we can quickly fill your requirements at the best prices, regardless the order size.
By Beatrice from Albania - 2018.12.11 14:13
This supplier's raw material quality is stable and reliable, has always been in accordance with the requirements of our company to provide the goods that quality meet our requirements.
By Paula from Miami - 2018.06.18 17:25